The gauge is designed to measure automatically airborne dust concentration and wind
speed and its direction in permanent places. The gauges can operate as individual dust pollution monitor
or in monitoring network. |
| Measuring range | 5-5000 µg/m3 in 7 subranges |
| Sensitivity of measurement | 2 µg/m3 for 24 h measuring cycle |
| Wind measurements | 16 discrete directions 0-60 m/s |
| Radiation source | Pm-147, 100 MBq |
| Air flow | 1 m3/h ± 2% |
| Dust deposition time | 30 min .. 24 h |
| Air filter | fiber glass band 40 m long |
| Digital port | CENTRONICS, RS232C |